利用時域反射技術測定飽和土壤中輕非水相液體的含量
發(fā)布時間:2017-12-28 18:14
本文關鍵詞:利用時域反射技術測定飽和土壤中輕非水相液體的含量 出處:《太原科技大學》2015年碩士論文 論文類型:學位論文
更多相關文章: 時域反射技術 飽和土壤 輕非水相液體 介電常數(shù) 電導率 混合介電模型
【摘要】:時域反射技術(TDR,Time-Domain-Reflectometry)是一種利用電磁波在介質中的傳播時間來確定介質性質的探測技術,已經被廣泛應用于工業(yè)和農業(yè)等多個領域。利用TDR測定土壤中輕非水相液體(LNAPLs,Light Non-aqueous Phase Liquids)的含量具有快速、準確、可連續(xù)原位測定、無輻射以及不破壞土壤樣品等優(yōu)點。目前,國內外利用TDR監(jiān)測輕非水相液體的相關研究還較為薄弱,LNAPLs對土壤介電特性的影響以及污染土壤中LNAPLs含量的定量預測相對較少。本研究利用時域反射技術,測定飽和砂土和壤土的介電常數(shù)和電導率隨LNAPLs(菜籽油、機油)含量的變化規(guī)律,并在此基礎上,通過模型模擬及修正,確定了飽和土壤中輕非水相液體含量的預測模型。結果表明:1)飽和土壤中體積含油量在0-0.05 m3m-3時,土壤介電常數(shù)并無顯著變化;隨著LNAPLs體積含量的進一步增加,介電常數(shù)呈線性減小趨勢;土壤容重和LNAPLs類型對相同飽和度的土壤介電常數(shù)未產生影響。2)飽和土壤的電導率與LNAPLs含量存在良好的線性負相關關系(R2=0.96);土壤容重對相同飽和度的土壤電導率未產生影響。3)混合介電模型(α=0.5)高估了飽和土壤中輕非水液體含量,平均RMSE為0.038cm3cm3;參數(shù)α調整為0.52后,混合介電模型提高了預測精度,比原混合介電模型(α=0.50)預測精度可以提高23.2%—30.4%。本研究結果表明可利用時域反射技術監(jiān)測污染土壤的介電常數(shù)與電導率并測定飽和土壤中LNAPLs的含量。
[Abstract]:TDR (Time-Domain-Reflectometry) is a detection technology based on the propagation time of electromagnetic waves in the medium to determine the properties of medium. It has been widely applied in many fields, such as industry and agriculture. The determination of LNAPLs, Light Non-aqueous Phase Liquids in soil by TDR is fast, accurate, continuous, in situ measurement, no radiation and no damage to soil samples. At present, the related researches on monitoring light nonaqueous phase liquids by TDR at home and abroad are relatively weak. LNAPLs has little influence on the dielectric properties of soil and the quantitative prediction of LNAPLs content in contaminated soil. This study uses time domain reflectometry, determination of saturated sand and loam soil permittivity and conductivity with LNAPLs (rapeseed oil, oil) the change rules of the content, and on this basis, through the simulation and correction model, the prediction model of LNAPL content in soil. The results show that: 1) the volume of soil saturated oil amount in 0-0.05 m3m-3, no significant changes of soil dielectric constant; with a further increase of LNAPLs content, the dielectric constant decreased linearly; on the same soil dielectric saturation, soil bulk density and LNAPLs type constant did not produce effect. 2) there is a good linear negative correlation between the conductivity of saturated soil and LNAPLs content (R2=0.96); soil bulk density has no effect on soil electrical conductivity of the same saturation. 3) the mixed dielectric model (alpha =0.5) overestimated the content of light and non-aqueous liquids in saturated soil, and the average RMSE was 0.038cm3cm3. When the parameter alpha was adjusted to 0.52, the mixed dielectric model improved the prediction accuracy, and the prediction accuracy of the mixed dielectric model (alpha =0.50) could be increased by 23.2% to 30.4%. The results of this study show that the time domain reflection technique can be used to monitor the dielectric constant and electrical conductivity of contaminated soil and determine the content of LNAPLs in saturated soil.
【學位授予單位】:太原科技大學
【學位級別】:碩士
【學位授予年份】:2015
【分類號】:X833
【相似文獻】
相關期刊論文 前6條
1 王清玉;;彈性波反射技術在樁檢中的應用效果及影響因素分析[J];勘察科學技術;1990年06期
2 劉斌 ,陳輝 ,劉爭平;時域反射技術在工程結構中的應用[J];電焊機;2004年05期
3 岳英潔;業(yè)渝光;刁少波;裴建新;趙廣濤;;時域反射技術應用與研究新進展[J];海洋湖沼通報;2007年S1期
4 金云;淺層高分辨率地震反射技術在采礦作業(yè)中的應用[J];中國煤炭;1996年05期
5 項友誼;肉制品中多種成分分析[J];食品科學;1983年06期
6 ;[J];;年期
相關會議論文 前1條
1 魏墨v,
本文編號:1346894
本文鏈接:http://www.wukwdryxk.cn/kejilunwen/huanjinggongchenglunwen/1346894.html
最近更新
教材專著