過渡流下多列叉排圓柱列流動傳熱特性對比研究
發(fā)布時間:2018-07-31 08:05
【摘要】:為了在過渡流狀態(tài)下對小型化換熱器叉排管束群的傳熱強化機理進(jìn)行研究,對三列、五列叉排圓柱列的流動傳熱特性的數(shù)值模擬結(jié)果進(jìn)行了對比研究。使用Fortran程序?qū)趶?fù)合網(wǎng)格系統(tǒng)的三列、五列叉排模型在不同橫向間距(Ps/D)下的流動傳熱特性進(jìn)行數(shù)值模擬。研究結(jié)果表明(1)當(dāng)Ps/D=3時,五列叉排圓柱列的傳熱強化效果最好,Ps/D=4時,三列叉排圓柱列的傳熱強化效果最好;(2)在叉排管束群中,第二列圓柱列的對流換熱效果最好,后排圓柱列的對流換熱效果依次降低。(3)在叉排管束群中,當(dāng)圓柱列列數(shù)增加時,Ps/D增大時,傳熱強化效果不明顯。
[Abstract]:In order to study the heat transfer enhancement mechanism of the cross row bundle group of miniaturized heat exchangers under the transition flow state, the numerical simulation results of the flow heat transfer characteristics of the three row and five row cross row columns were compared and studied. The flow heat transfer characteristics of a three-row, five-row cross row model based on a composite grid system under different transverse spacing (Ps/D) were simulated by Fortran program. The results show that (1) when Psr / D = 3, the heat transfer enhancement effect of the five-row intersected column is the best than that of PsP / D = 4, and (2) the convection heat transfer efficiency of the second row cylindrical column is the best in the cross row tube bundle group. The convection heat transfer efficiency of the back column decreases in turn. (3) in the cross row bundle group, when the column number increases, the heat transfer enhancement effect is not obvious when the column number increases.
【作者單位】: 南通大學(xué)機械學(xué)院;
【基金】:國家自然科學(xué)基金(51476080)
【分類號】:TB657.5
本文編號:2154952
[Abstract]:In order to study the heat transfer enhancement mechanism of the cross row bundle group of miniaturized heat exchangers under the transition flow state, the numerical simulation results of the flow heat transfer characteristics of the three row and five row cross row columns were compared and studied. The flow heat transfer characteristics of a three-row, five-row cross row model based on a composite grid system under different transverse spacing (Ps/D) were simulated by Fortran program. The results show that (1) when Psr / D = 3, the heat transfer enhancement effect of the five-row intersected column is the best than that of PsP / D = 4, and (2) the convection heat transfer efficiency of the second row cylindrical column is the best in the cross row tube bundle group. The convection heat transfer efficiency of the back column decreases in turn. (3) in the cross row bundle group, when the column number increases, the heat transfer enhancement effect is not obvious when the column number increases.
【作者單位】: 南通大學(xué)機械學(xué)院;
【基金】:國家自然科學(xué)基金(51476080)
【分類號】:TB657.5
【相似文獻(xiàn)】
相關(guān)期刊論文 前3條
1 巴德純,楊乃恒,王曉冬,王孝珍,朱岳,,龐世謹(jǐn);分子泵中螺旋通道在過渡流和滑流態(tài)抽氣特性的研究[J];真空;1995年01期
2 巴德純,劉波,王曉冬,楊乃恒,于治明;盤型分子泵3D過渡流特性[J];真空科學(xué)與技術(shù)學(xué)報;2004年01期
3 ;[J];;年期
相關(guān)會議論文 前1條
1 于治明;王曉冬;巴德純;楊乃恒;;螺旋槽式渦輪增壓泵過渡流分子運動規(guī)律分析[A];中國真空學(xué)會第六屆全國會員代表大會暨學(xué)術(shù)會議論文摘要集[C];2004年